Free NS0-176 sample questions
Real questions from the Cisco and NetApp FlexPod Implementation and Administration practice bank, with the correct answer and an explanation for each one. No junk, no filler.
Try them in the simulator Same questions, with study, timed and flashcard modes.
Showing 10 of 20 free sample questions.
A solutions architect is designing a new FlexPod environment for a mixed-workload VDI deployment. A key requirement is to provide consistent, low-latency performance for persistent desktops while also cost-effectively storing user profile data that is accessed less frequently. Which NetApp storage configuration best meets these requirements within a single storage system?
An administrator is troubleshooting a SAN boot issue where a newly provisioned Cisco UCS B-Series blade fails to see its boot LUN from a NetApp AFF array. The zoning on the Cisco MDS switches is confirmed correct, and other blades in the same chassis can boot successfully using similar service profile templates. The administrator observes that the vHBA on the failing blade remains offline. What is the most likely cause of this issue within the UCS Manager configuration?
A FlexPod administrator needs to perform a firmware upgrade on multiple Cisco UCS B-Series blades. To ensure consistency and minimize manual effort, the administrator decides to use policies within UCS Manager. Which TWO policies are essential for managing the firmware versions of the blade server components? (Select TWO)
True or False: In a standard FlexPod deployment, a vPC (Virtual Port Channel) peer-link must be established directly between the two Cisco UCS Fabric Interconnects to enable active-active uplinks.
A consultant is gathering requirements for a new FlexPod deployment that will host a sensitive database application. The customer has a strict security requirement that all administrative access to the NetApp storage system must be logged and auditable. Furthermore, management traffic must be isolated from data traffic. Which two components should be configured on the NetApp storage system to meet these requirements? (Select TWO)
When creating a Service Profile in Cisco UCS Manager, an administrator needs to assign a unique identifier to the server's virtual HBAs that will be used for SAN booting. From which pool is this identifier drawn?
A financial firm requires a FlexPod design that can survive a complete site failure with zero data loss (RPO=0) and a near-zero recovery time (RTO). The two sites are 50 km apart and have high-bandwidth, low-latency dark fiber links. Which combination of NetApp technology and Cisco networking design should be proposed?
**Case Study:** A healthcare organization is refreshing its data center with a new FlexPod solution to support its Electronic Health Record (EHR) system. The solution must comply with HIPAA regulations, which mandate data encryption at rest and strict access controls. The current environment consists of physical servers that will be virtualized onto the new platform. The project requirements are as follows: 1. All patient data stored on the NetApp array must be encrypted. 2. The virtualization platform will be VMware vSphere. 3. Network traffic for vMotion and storage access must be isolated from the main production network. 4. The solution must be built according to the latest Cisco Validated Design (CVD) for FlexPod with VMware. An administrator is tasked with the initial storage configuration on a NetApp AFF A250 system. To meet the encryption requirement, the administrator enables NetApp Volume Encryption (NVE). For network isolation, separate VLANs and dedicated vNICs in the UCS service profiles are planned for vMotion and iSCSI traffic. What additional step is crucial for securing data access on the newly created iSCSI LUNs that will host the VMware datastores?
A FlexPod administrator observes high network utilization alerts from OnCommand Unified Manager for a specific SVM. Investigation reveals that a single, high-traffic virtual machine is consuming a disproportionate amount of bandwidth. Which feature, configured in both Cisco UCS Manager and the Nexus switches, can be used to limit the bandwidth for the vNIC associated with this VM?
10 more free samples are waiting
Create a free account to unlock the whole NS0-176 sample bank, or get full access to all 211 practice questions in the simulator.