ExamDumpster

Free H13-624-V5-5 sample questions

Work through these free H13-624-V5-5 sample questions, each with an answer and an explanation. They cover OceanStor Smart and Hyper features, installation and performance tuning. Use them to see where your hands-on storage knowledge is thin.

Try them in the simulator Same questions, with study, timed and flashcard modes.

Showing 10 of 20 free sample questions.

Question 1Choose one

When expanding capacity on a live OceanStor Dorado system using RAID 2.0+, an engineer adds a new disk enclosure with 25 SSDs. What is the process for incorporating these new disks into an existing storage pool?

Question 2Choose one

An administrator is using the Huawei-provided toolkit for initial device deployment. Which tool in this kit is specifically used to perform the initial configuration and IP address assignment for a new OceanStor storage system?

Question 3Choose one

A database administrator reports intermittent high latency during write operations on a LUN hosted on a Huawei OceanStor array. A storage administrator uses performance monitoring tools and observes that the write cache of the storage system is frequently reaching its high watermark, causing forced de-staging to backend disks. Which of the following is the most likely cause for this write cache behavior?

Question 4Choose one

**Case Study** A mid-sized manufacturing company, 'ManuCorp', is modernizing its IT infrastructure. They have two data centers located in the same metropolitan area, 15 km apart, connected by a dedicated dark fiber link with less than 1ms of round-trip latency. Their most critical application is an ERP system running on a physical server cluster that requires continuous availability and zero data loss (RPO=0) in the event of a site failure. ManuCorp has purchased two identical Huawei OceanStor Dorado 6000 V6 arrays, one for each data center. The storage will be presented to the server cluster via an existing 16Gb Fibre Channel SAN fabric that spans both sites. The solution must provide for automatic, transparent failover of storage services between the sites without requiring manual intervention or server-side scripting. The project team is evaluating different Huawei data protection features. The primary business requirement is to maintain ERP system uptime during a full data center outage. The secondary requirement is to perform non-disruptive disaster recovery testing. Which Huawei storage solution should the architect implement to meet all of ManuCorp's requirements?

Question 5Choose one

When using Huawei UltraPath on a Linux host connected to an OceanStor array, an administrator needs to check the status of all logical paths to the storage, including which paths are active and which are standby. Which command should the administrator use?

Question 6Choose one

A storage consultant is performing a pre-installation review for a new Huawei OceanStor Dorado 5000 V6 that will serve iSCSI traffic to a cluster of database servers. To ensure security and performance isolation, what is the recommended best practice for connecting the array's management and service network ports?

Question 7Choose 2

A healthcare provider is deploying a new Huawei OceanStor Pacific system to store large medical imaging files (DICOM). The primary requirements are high data durability and optimal storage space efficiency, as the data must be retained for many years. Which TWO of the following configurations are most suitable for this use case? (Select TWO)

Question 8Choose one

True or False: When performing a non-disruptive upgrade (NDU) of controller firmware on a dual-controller Huawei OceanStor Dorado array, the system upgrades both controllers simultaneously to minimize the duration of the maintenance window.

Question 9Choose one

An administrator adds several new disks of the same type to an existing disk domain on a live OceanStor Dorado system that uses RAID 2.0+. What is the expected system behavior after the disks are successfully integrated?

Question 10Choose one

An administrator receives a critical alarm on an OceanStor Dorado array indicating a disk has failed and its status is 'Faulty'. A global hot spare disk has already been activated and the RAID group is rebuilding. What is the correct and safest procedure for replacing the faulty disk?

10 more free samples are waiting

Create a free account to unlock the whole H13-624-V5-5 sample bank, or get full access to all 217 practice questions in the simulator.

Create account