Free FCSS-NST-SE-7.6 sample questions
Work through these free FCSS-NST-SE-7.6 sample questions; each one has the answer and an explanation. They cover FSSO faults, BGP and OSPF problems and IPsec tunnels that will not come up. Try to name the cause before you read the explanation.
Try them in the simulator Same questions, with study, timed and flashcard modes.
Showing 10 of 20 free sample questions.
A network engineer is troubleshooting FSSO. Users who are members of the 'Domain Admins' group are being correctly identified, but users who are only members of the 'Sales_Users' group are not appearing in the FSSO user list on the FortiGate. The FSSO Collector Agent is running in Advanced mode with DC Agents installed. What is a common misconfiguration that would cause this specific issue? sequenceDiagram participant User participant DC as Domain Controller participant DCAgent as DC Agent participant Collector as Collector Agent participant FGT as FortiGate User->>DC: Logon Event (Sales_Users) DC->>DCAgent: Forward Logon Event DCAgent->>Collector: Send User Info Note over Collector: Group Filter applied Collector-->>FGT: No update sent (User filtered out)
During a connectivity test, an administrator uses the command `execute traceroute-options device auto` followed by `execute traceroute `. The goal is to trace a path for traffic originating from the LAN interface. However, the trace appears to be sourcing from the WAN interface instead. What is the most likely reason for this behavior?
A FortiGate running FortiOS 7.6.1 has an IKEv2 site-to-site tunnel configured with `set transport auto`. The remote peer sits behind a firewall that blocks UDP 500/4500. `diagnose debug application ike -1` shows the message `auto transport timeout, use tcp port 4500`, and the tunnel then comes up. What does this message indicate?
An OSPF network is configured with a hub-and-spoke topology. The hub FortiGate is redistributing a default static route into OSPF. The spoke FortiGates are learning the default route but are not installing it in their routing tables. All OSPF adjacencies are FULL. What setting on the spoke FortiGates would prevent the installation of the redistributed default route?
A FortiGate is configured to use a RADIUS server for administrator authentication. An administrator is unable to log in. The output of the debug command `diagnose debug application fnbamd -1` shows the RADIUS server sending an `Access-Reject` message. The administrator is certain the password is correct. Which of the following is a plausible reason for the `Access-Reject` message in this scenario?
True or False: When configuring a policy-based static route in FortiOS, if the incoming packet matches the policy route criteria, the FortiGate will bypass the regular FIB (Forwarding Information Base) lookup for that packet.
After a firmware upgrade to FortiOS 7.6, a FortiGate 100F enters conserve mode. The output of `diagnose hardware sysinfo memory` shows that `Slab` (kernel slab) memory is extremely high. Which of the following is a likely cause of high kernel slab memory usage?
A support engineer is using the packet sniffer on a FortiGate with the command `diagnose sniffer packet any 'host 10.1.1.1 and host 8.8.8.8' 4 0 l`. What is the purpose of the `l` argument at the end of this command?
An administrator is troubleshooting a dial-up IPsec VPN where remote users are assigned virtual IP addresses from a specific IP pool. One user reports that they are unable to connect. The IKE debug shows that Phase 1 completes successfully, but Phase 2 fails. The logs indicate a `NO_PROPOSAL_CHOSEN` error during Quick Mode. What is a common cause for this error in a dial-up VPN scenario?
10 more free samples are waiting
Create a free account to unlock the whole FCSS-NST-SE-7.6 sample bank, or get full access to all 196 practice questions in the simulator.