Free D-PVM-DS-01 sample questions
Each free D-PVM-DS-01 sample question below shows the answer and explains it. The questions cover SnapVX and SRDF replication, upgrade planning and PowerMax File. Use them to test your design choices before booking.
Try them in the simulator Same questions, with study, timed and flashcard modes.
Showing 10 of 20 free sample questions.
A media company uses SRDF/A to replicate large video files to a remote data center for disaster recovery. They are experiencing consistently high RPO times, and analysis shows the SRDF links are saturated. The network team cannot provide more bandwidth. Which SRDF feature can be implemented on the PowerMax arrays to reduce the amount of data sent over the SRDF links?
An administrator is using Unisphere for PowerMax to monitor a virtualized environment. They need to quickly identify which datastores are consuming the most IOPS and have the highest latency, and then correlate that activity back to specific VMs. Which Unisphere feature provides this level of end-to-end visibility?
A PowerMax 2500 is being upgraded with additional drive capacity and new directors to increase performance. Which classification of configuration change does this represent?
Which of the following statements accurately compares the PowerMax 2500 and PowerMax 8500 models?
A financial firm requires an active/active data center solution for its tier-1 trading application to ensure continuous availability and zero RPO over a distance of 60 km. The solution must provide a single, consistent copy of data accessible from both sites simultaneously and automate failover in the event of a full site outage. Which SRDF mode is designed specifically for this requirement?
**Case Study:** A large e-commerce company is experiencing performance issues with its primary order database, which runs on a PowerMax 8500. The CIO has requested a detailed workload analysis to plan for a hardware upgrade. The storage team needs to use Unisphere for PowerMax to determine the peak IOPS, average latency, and required storage capacity for the next 12 months based on a 20% annual growth rate. The analysis must exclude non-critical, temporary data generated by nightly batch jobs to avoid skewing the results. Which Unisphere for PowerMax features must the team use to generate an accurate forecast for this specific requirement?
What is the fill-in-the-blank value in the following SYMCLI command used to create a new TimeFinder SnapVX snapshot of a device group named 'ORA_DG' with a time-to-live of 2 days? `symsnapvx -g ORA_DG establish -name DailyBackup_2300 -____ 2`
A manufacturing company is upgrading its PowerMax 2500 by adding a new drive enclosure. The lead engineer is concerned about ensuring the new hardware is correctly integrated and the system remains stable. What is the most critical rule to follow during a PowerMax hardware upgrade?
A solutions designer is creating a disaster recovery plan involving three data centers (A, B, C) using PowerMax arrays. The goal is to have Site B act as a bunker, receiving synchronous replication from Site A. From the bunker site (B), asynchronous replication must be sent to the remote site (C). What does this SRDF topology represent? graph TD subgraph Site A (Primary) P1[Production] end subgraph Site B (Bunker) R1[Sync Copy] end subgraph Site C (Remote DR) R2[Async Copy] end P1 -- SRDF/S --> R1 R1 -- SRDF/A --> R2