Free D-PE-OE-01 sample questions
Here are free D-PE-OE-01 sample questions on PowerEdge operations, each answered and explained. Questions deal with iDRAC management, firmware updates and fixing hardware faults. Try them before booking to see where you stand.
Try them in the simulator Same questions, with study, timed and flashcard modes.
Showing 6 of 12 free sample questions.
In a high-density datacenter environment with stringent thermal envelope limits, a systems administrator must cap the maximum air exhaust temperature of a PowerEdge server at 50°C. In the command racadm set system.thermalsettings.AirExhaustTemp _____, the correct parameter value that configures the 50°C limit is:
A systems operations engineer is managing an isolated edge datacenter with 18 PowerEdge servers running iDRAC 10. Following an automated firmware update cycle to iDRAC 10 version 1.20.80.50, an edge application orchestration tool encounters recurring API authentication timeout issues. The decision is made to roll back the iDRAC firmware to the previously installed firmware build. The engineer connects to the iDRAC firmware RACADM prompt on the first server and executes: racadm rollback iDRAC.Embedded.1-1 The command fails immediately with a validation error indicating that the rollback cannot proceed in the current configuration. The engineer verifies that: - The engineer is logged in with an account having Configure privileges. - Running racadm swinventory confirms that Rollback Version is listed as Available for iDRAC.Embedded.1-1. - The job queue (racadm jobqueue view) contains no scheduled, running, or staged jobs. - The iDRAC NIC is currently configured to use Shared LOM mode across the server's embedded Ethernet interfaces. What action must the engineer perform before the iDRAC firmware rollback operation can succeed?
An infrastructure team plans to standardize BIOS and component settings across 50 PowerEdge servers using Server Configuration Profiles (SCP). The team wants to validate attribute syntax and check for potential configuration errors on target servers without rebooting or applying any changes to the running system. Which feature and licensing condition satisfy this requirement?
True or False: Applying an iDRAC firmware update using the RACADM CLI or the iDRAC web interface requires the embedded Lifecycle Controller to be in an enabled state, whereas executing the iDRAC Dell Update Package (DUP) directly within a supported host operating system does not require the Lifecycle Controller to be enabled.
A PowerEdge server experiences an uncorrectable multi-bit memory error resulting in an automated system restart. An engineer needs to query the hardware-level BMC sensor events to identify the failing DIMM slot, rather than viewing the chronological record of administrative configuration changes. Which RACADM command should the engineer execute?
6 more free samples are waiting
Create a free account to unlock the whole D-PE-OE-01 sample bank, or get full access to all 150 practice questions in the simulator.