Correct answers: The server ports on the Fabric Interconnect are configured as 'Appliance' ports.; The IOM (FEX) modules in the chassis are physically unseated or have no power.
Server ports must be configured as 'Server' ports. If configured as Appliance, Monitor, or Uplink ports, the FI will not attempt the discovery protocol for a blade chassis connection, resulting in a physical link but no logical discovery (or link down appearance in logical view).
If the I/O Modules are not powered or seated correctly, the physical link cannot come up. The 'Link Down' status in the FSM specifically points to layer 1/2 connectivity issues between the FI and the Chassis IOM.