Question 1Choose one

A multinational medical device manufacturer recently transitioned to a fully electronic Quality Management System (eQMS). During an FDA inspection, the investigator focuses on the data integrity of the environmental monitoring records in the ISO Class 7 cleanroom. The facility uses automated particle counters that transmit data wirelessly to a central server. The investigator discovers that while the system logs the time and date of particle counts, the generic login 'Cleanroom_Tech' is used by all operators on the shift to acknowledge alarms. Furthermore, the system allows supervisors to overwrite alarm acknowledgment comments without retaining the original text. The firm argues that the raw particle count data cannot be altered, thus ensuring data integrity. Evaluate the scenario based on ALCOA principles. Which specific ALCOA elements are primarily violated by the current system configuration?

Question 2Choose 2

During a QSIT-based audit of the Production and Process Controls subsystem, the auditor is evaluating the environmental controls of a facility manufacturing sterile implants. Which TWO methods of objective evidence collection would yield the most reliable verification of continuous compliance? (Select TWO)

Question 3Choose one

The lead auditor is conducting the opening meeting for a recertification audit to ISO 13485:2016. Which of the following elements MUST be established and communicated to the auditee's management during this meeting?

Question 4Choose one

Upon finalizing the audit report for a complex Class III device manufacturer, the lead auditor notes a systemic failure in the design transfer process. To maximize the impact and clarity of this finding for executive management, how should the nonconformance be presented in the report?

Question 5Choose one

Six months after issuing a major nonconformance regarding inadequate supplier evaluation, the auditor returns to verify the effectiveness of the CAPA. The auditee presents a newly revised SOP for supplier qualification. What additional evidence is absolutely necessary for the auditor to verify the effectiveness of this corrective action?

Question 6Choose one

Under the FDA's Quality System Inspection Technique (QSIT), if an investigator is conducting a 'Level 2' (Comprehensive) inspection, which subsystems are mandatory to cover?