ExamDumpster

Free SPI sample questions

Real questions from the Sonography Principles and Instrumentation practice bank, with the correct answer and an explanation for each one. No junk, no filler.

Try them in the simulator Same questions, with study, timed and flashcard modes.

Showing 10 of 20 free sample questions.

Question 1Choose one

A sonographer is performing a carotid artery duplex exam and observes spectral broadening in the internal carotid artery waveform. Which of the following is the LEAST likely cause for this observation?

Question 2Choose one

While imaging the liver, a sonographer encounters a highly echogenic, well-defined mass that causes a significant decrease in the amplitude of the sound beam, resulting in a dark area posterior to the structure. This artifact is best described as:

Question 3Choose one

The acoustic impedance of a medium is a critical factor in determining the amount of reflection at an interface. It is calculated as the product of which two properties of the medium?

Question 4Choose one

A sonographer is using a transducer with a wide bandwidth. Which of the following characteristics is most associated with this type of transducer?

Question 5Choose 2

In accordance with the ALARA (As Low As Reasonably Achievable) principle, which TWO of the following actions should a sonographer prioritize to minimize patient exposure to ultrasound energy? (Select TWO)

Question 6Choose one

A sonographer is having difficulty visualizing blood flow in a deep abdominal vessel using Color Doppler. The color box is filled with random, multi-colored pixels that do not correspond to true blood flow. Which control should be adjusted FIRST to resolve this issue?

Question 7Choose one

During an obstetric exam, the sonographer switches from B-mode to tissue harmonic imaging (THI). What is the primary advantage of using THI in this context?

Question 8Choose one

The decibel (dB) scale is used to quantify the strength of ultrasound signals. If a signal's intensity is reduced to one-tenth of its original value, what is the corresponding change in decibels?

Question 9Choose one

True or False: The matching layer of an ultrasound transducer is designed to have an acoustic impedance that is the geometric mean of the impedances of the piezoelectric crystal and the skin.

Question 10Choose one

When performing quality assurance checks on an ultrasound system using a standard tissue-mimicking phantom, a sonographer measures the 'dead zone'. What does this measurement evaluate?

10 more free samples are waiting

Create a free account to unlock the whole SPI sample bank, or get full access to all 180 practice questions in the simulator.

Create account